AMiquam Reports 0.1 mm Indications in LPBF In-Situ Eddy Current Inspection

The Swiss company says its recoater-mounted sensor can map small flaw indications to part coordinates, with heat-exchanger and blade examples.

AMiquam, a Swiss technology company, has reported sensitivity gains in its in-situ eddy current inspection method for metal additive manufacturing, saying it detected indications as small as 0.1 mm in thin-walled parts made by laser powder bed fusion. The results were presented in a technical publication ahead of Formnext 2026.

The approach moves inspection into the build chamber. An eddy current sensor is integrated into the recoater assembly of an LPBF machine. As the recoater passes over the build platform, it scans each newly deposited layer and records electromagnetic signals associated with internal defects. The data is then mapped to the component geometry, so anomalies can be located and reported automatically.

AMiquam positions this as a complement to, or partial alternative to, post-build non-destructive testing. Instead of waiting until a part is finished, manufacturers could gather inspection evidence layer by layer. The company says this could be useful for complex internal channels and safety-critical parts, though it has not presented the method as a universal replacement for existing qualification routes.

Thin-wall heat exchanger test

In one demonstration, AMiquam inspected a 316L stainless steel test specimen with a wall thickness of 0.7 mm. Five artificial holes ranging from 0.1 mm to 0.5 mm in diameter were introduced. Both through-holes and blind holes produced distinct peaks in the eddy current signal, and even the smallest 0.1 mm indication was distinguishable from background variation.

The measurements covered about 127 layers. Each hole generated a corresponding signal peak as the build progressed, according to the company. AMiquam says the results point to potential use in complex structures such as triply periodic minimal surface heat exchangers, where thin walls and internal channels make conventional post-process inspection difficult.

Blade geometry and detection limits

A second application involved LPBF-manufactured aeroengine blades. The blade design used a conformal laser scanning strategy in the surface skin and a conventional chessboard scanning approach in the bulk. These strategies create different microstructures, which in turn affect the eddy current signals recorded during inspection.

AMiquam reports detection capability of about 0.2 mm in the conformal skin. In the bulk material, the threshold is about 0.5 mm, because microstructural variation adds signal fluctuations that make smaller indications harder to separate. The company notes that sensitivity depends on material characteristics, laser scanning strategy and component geometry, and says optimising laser strategies could improve performance in bulk regions.

From signal to location

The system is also designed to locate indications, not merely flag process instability. Eddy current signals from each recoating step are mapped onto the part geometry. Software identifies indications that exceed predefined thresholds and assigns coordinates in X, Y and build-layer positions.

That spatial record could help manufacturers investigate where defects occur and what caused them. Capturing data throughout the build may also give earlier warning of quality issues, rather than revealing them only after the component is complete.

Qualification context

AMiquam also describes a concept for an inspection certificate covering material, layer coverage, detection limits and detected indications. The document would provide a structured record of inspection data generated during manufacture. The certificate shown in the publication is an illustrative example, not an actual component certification.

The company argues that in-process inspection could be valuable in aerospace, energy and medical manufacturing, where qualification and traceability matter and post-build inspection can be time-consuming. It cautions, however, that the reported detection thresholds are application-specific and depend on geometry, material and process parameters. They should not be read as universal performance limits.

NB

Nadia Belmonte

Nadia Belmonte covers analytical laboratory instruments and weighing systems, including HPLC, spectrophotometers, pH meters, analytical balances, and checkweighers. Her evidence reviews detection limits, repeatability, weighing intervals, sample preparation effects, and calibration uncertainty against stated method requirements, while checking applicable standards such as ISO/IEC 17025 for laboratory competence and OIML R 76 for non-automatic weighing instruments. She helps laboratory managers, quality engineers, and procurement teams evaluate instrument suitability, maintenance needs, and lifecycle cost without treating any single specification as a universal guarantee.