Water recycling is an increasingly important tool for greenhouse growers who want to conserve water, improve efficiency and cut nutrient and pesticide losses. But recycling irrigation water brings its own problem: runoff can carry fertilizers and crop protection products back into storage tanks, where those materials accumulate over time.
Researchers at Michigan State University, supported by the American Floral Endowment (AFE), are exploring a notably simple candidate solution — woodchips. The work is led by Dr. Tom Fernandez.
How a woodchip bioreactor works
A woodchip bioreactor is essentially a tank or treatment area packed with woodchips through which water is passed. The wood gives beneficial microorganisms a surface to grow on and supplies the carbon that fuels microbial activity. Woodchips can also physically bind, or adsorb, some contaminants.
Such systems have already been used in agriculture to remove nitrate from drainage water. Fernandez's research has also shown that woodchip systems can remove phosphorus and pesticides when the time water spends inside the bioreactor is increased.
Two stages, two oxygen levels
For this project the team took the concept a step further with a two-stage treatment system. Water first passes through a non-aerated woodchip bioreactor where oxygen levels remain relatively low, then moves into a second woodchip bioreactor that is continuously aerated. The arrangement matters because different microorganisms thrive under different oxygen conditions, and some pesticides may break down more effectively under aerobic conditions while others respond better to low-oxygen environments.
Field trial at a Michigan wholesale greenhouse
The researchers moved beyond the laboratory and installed bioreactors at a wholesale greenhouse in Michigan. The system treated return water from roughly 11,500 square meters of greenhouse production. Two differently sized systems were tested: in one, water remained in each treatment stage for about 30 minutes, and in the larger system for about 60 minutes. Water was collected throughout the production season and analyzed for nutrients, water-quality characteristics and hundreds of pesticides.
Early results
Early results show the two-stage systems successfully created the different oxygen conditions the researchers were seeking, which allowed them to study how those environments affected nutrient recycling and pesticide treatment.
Importantly, the systems generally retained a high percentage of the nitrogen and phosphorus already present in the irrigation water. Nitrogen recycling often exceeded 80% and, under some conditions, averaged about 91%. Phosphorus recycling was also high in the initial non-aerated treatment stage. The systems needed an initial acclimation period, but their performance became more stable as the season progressed.
Further detail on pesticide removal and on the concentration levels detected during the recycled-irrigation tests is available in the original article by Fernandez and Laura Barth published by AFE.
AFE is an independent nonprofit organization that funds research and scholarships in floriculture and environmental horticulture for the benefit of growers, wholesalers, retailers, allied industry organizations and the general public.